Blog
Construction Design Services in Pakistan: The Complete Guide for Owners and Investors
Construction Design Services in Pakistan: The Complete Guide for Owners and Investors
A plot owner in Lahore buys a 10 marla plot, hires a contractor on a recommendation, and starts digging within a month. There are no structural drawings. The mason decides the column sizes on site. Six months later, the authority asks for an approved plan, and the owner learns that the building does not match the setback or structural requirements.
This happens often. Construction costs money once, but design mistakes cost money repeatedly: in rework, in delays, in approval rejections and, in the worst case, in safety.
This guide explains what construction design includes, who is legally allowed to do it in Pakistan, how the process runs step by step, and what to check before you hire a design firm. It is written by the engineering team at Qalam Engineering, based in Bahria Town, Lahore.
What Is Construction Design?
Construction design is the planning and drawing work done before any building work starts. It turns your idea and your plot into a set of drawings and documents that engineers, authorities and contractors can follow.
A complete design package normally covers three disciplines:
- Architectural design: layout, floor plans, elevations, sections, and compliance with setbacks and building regulations.
- Structural design: foundations, columns, beams, slabs and reinforcement, designed to carry loads safely.
- MEP design: mechanical (HVAC), electrical and plumbing systems, including drainage and fire protection.
Design is separate from construction. A design firm prepares the drawings. A contractor builds from them. Some companies, including Qalam Engineering, offer both under one roof, but the design stage should still be complete before the first brick is laid.
Why Design Comes Before Construction
Design is where the cheapest decisions are made. Moving a wall on paper costs nothing. Moving a column after the slab is cast costs a great deal.
Good design also does four practical things:
- Gives you a bill of quantities (BOQ) before you spend, so you can budget realistically.
- Gives contractors the same drawings to quote against, which makes bids comparable.
- Provides the documents required for building plan approval.
- Reduces the chance of structural problems, especially in a seismic country like Pakistan.
Who Is Allowed to Do Construction Design in Pakistan?
This is the part most competitor articles skip, and it affects you legally.
Structural drawings submitted for approval must be prepared and signed by a structural engineer registered with the Pakistan Engineering Council (PEC). Punjab local government application requirements, for example, ask for structural design documents signed by a PEC-registered structural engineer.
Architectural drawings are prepared by architects registered with the Pakistan Council of Architects and Town Planners (PCATP). Some authorities, including LDA, also maintain their own registration of architects and town planners.
Before hiring, ask the firm for:
- PEC registration number (for engineering work)
- PCATP registration of the architect
- Names of the engineers who will sign the drawings
You can verify PEC registration with PEC directly. If a firm will not share these details, treat that as a warning.

Building Codes That Apply in Pakistan
Pakistan’s main structural reference is the Building Code of Pakistan (BCP), developed by PEC.
- The Seismic Provisions 2007 set minimum requirements for earthquake-resistant design of reinforced concrete, steel, masonry and timber buildings.
- BCP 2021, developed by PEC with the International Code Council, is based on the 2021 International Building Code and sets minimum benchmarks for structural safety in design and construction.
- PEC has also issued provisions on energy and fire safety.
Why this matters to you: Pakistan sits in an active seismic region. A design that ignores seismic provisions may look fine on paper but fails where it counts. Ask your engineer which code edition and which seismic zone they are designing for, and why.
One more point. City bylaws control architectural planning such as setbacks, coverage and height. Academic research on Pakistan’s regulatory system notes that such bylaws do not themselves regulate structural analysis and design. So approval of an architectural plan does not prove your structure is safe. The structural design must be checked separately.
The Construction Design Process, Step by Step

1. Brief and site survey
The firm collects your requirements, budget range, plot documents and a topographic or boundary survey.
2. Soil investigation
A geotechnical test tells the engineer the bearing capacity and soil behaviour. Foundation design depends on it. Skipping this step is one of the most common and costly shortcuts.
3. Concept design
The architect prepares layout options and a basic 3D view. You approve the direction before details are drawn.
4. Design development
Dimensions, materials and services are fixed. Structural and MEP engineers coordinate with the architect so that beams do not clash with ducts and pipes.
5. Structural analysis and design
The engineer models the building, applies loads including seismic and wind, and designs the foundations and frame.
6. Working drawings
Detailed drawings that the contractor builds from: plans, sections, reinforcement details, electrical and plumbing layouts.
7. Approval submission
The documents go to the relevant authority. Many authorities ask for architectural drawings, structural drawings and calculations, and site plans, among other documents.
8. Tender documents and BOQ
The BOQ and specifications let you invite comparable quotes from contractors. A good firm can also supervise construction to check that the building follows the drawings.
What a Complete Design Package Should Include
Use this table as a checklist when comparing quotes:
| Document | What it is for |
|---|---|
| Architectural drawings | Layout, elevations, sections, setback compliance |
| Structural drawings | Foundation, columns, beams, slabs, reinforcement details |
| Structural calculations | Proof of design, needed for approval and review |
| MEP drawings | HVAC, electrical, plumbing, drainage, fire fighting layouts |
| BOQ | Quantities and budget estimate |
| Specifications | Material grades and quality requirements |
| 3D views | Visual approval before construction |
If a quote mentions only “map” or “plan”, ask what exactly is included. A floor plan alone is not a design package.
Approval Authorities by City
Approval depends on where your plot is. The authority and its rules differ, so confirm requirements with the local office before you start.
| City | Usual approving body | Note |
|---|---|---|
| Lahore | Lahore Development Authority (LDA) | Housing societies such as Bahria Town may have their own approval process. Check with the society. |
| Islamabad | Capital Development Authority (CDA) | Separate rules for housing schemes |
| Rawalpindi | Rawalpindi Development Authority (RDA) | |
| Faisalabad | Faisalabad Development Authority (FDA) | |
| Multan | Multan Development Authority (MDA) | |
| Gujranwala | Gujranwala Development Authority (GDA) | |
| Peshawar | Peshawar Development Authority (PDA) | |
| Karachi | Sindh Building Control Authority (SBCA) | |
| Sialkot, Gujrat, Sargodha, Jhang | Local development authority or Tehsil Municipal Administration | Verify with the local office |
In Lahore, LDA has issued Building and Zoning Regulations (2019) and later approved updated building regulations. Rules and processing times change, so always check the current version before you pay for drawings.
What Affects the Cost of Construction Design?
No honest firm can give a fixed price without knowing your project. These factors move the fee:
- Size and number of floors. More area and height mean more structural work.
- Building type. A house, plaza, factory and warehouse each have different loads and services.
- Scope. Architectural only, or architectural plus structural plus MEP.
- Complexity. Basements, large spans, heavy machinery and irregular shapes need more analysis.
- Extras. 3D renders, BIM modelling, BOQ and supervision.
Firms usually quote in one of three ways: per square foot, as a percentage of construction cost, or as a lump sum. Ask for the scope in writing so you can compare quotes properly.
Design Needs by Project Type
Residential (houses and apartments)
Focus on setbacks, light, ventilation and efficient layouts. Structural design should still follow seismic provisions, even for a small house.
Commercial (plazas, offices, shops)
Parking, fire exits, services, and often higher-rise structures. Larger projects may need extra clearances. For example, some authority requirements ask for traffic-related NOCs for bigger plots and taller buildings.
Industrial (factories and warehouses)
Large spans, crane loads, heavy floors and machinery foundations. Steel structures are common. Industrial layouts also need process flow, power supply and drainage planned early.
Qalam Engineering works on industrial and commercial projects across sectors, so we start industrial designs from the process requirement, not from the building shape.
Common Design Mistakes and How to Avoid Them
- Starting construction before design is finished. Decisions made on site are rarely engineered.
- Skipping soil testing. Foundations designed on assumption can be over- or under-designed.
- Using unregistered designers. Your drawings may be rejected and you carry the risk.
- Ignoring MEP coordination. Pipes and ducts get cut through beams later.
- Comparing quotes without comparing scope. The cheaper quote may leave out structural calculations or BOQ.
- No provision for future floors. If you plan to add floors later, tell the engineer now. Adding load to a building not designed for it is unsafe.
- Changing the design during construction without engineer approval.
How to Choose a Construction Design Company
Ask these questions:
- Are your engineers PEC-registered, and who signs the drawings?
- Which building code and seismic provisions do you design to?
- Can you show completed projects similar to mine?
- What exactly is in the package, and what is extra?
- Do you handle approval submission, and which authorities have you dealt with?
- Can you supervise construction or review the contractor’s work?
Beyond the answers, look at how the firm explains things. A competent engineer can explain a decision in plain words.
How Qalam Engineering Works
Qalam Engineering provides end-to-end, high-quality solutions for industrial and commercial projects in diverse sectors. Our office is at Overseas Enclave, Block C, Bahria Town, Lahore, Punjab, Pakistan.
We serve clients in Lahore, Islamabad, Rawalpindi, Gujranwala, Gujrat, Sialkot, Faisalabad, Multan, Sargodha, Jhang, Peshawar and Karachi.
To discuss your project, call +92 309 5185285 or visit our Bahria Town office. Bring your plot documents and any existing drawings.
Frequently Asked Questions
What is included in construction design services?
Construction design usually includes architectural drawings, structural design and calculations, MEP drawings, a BOQ and specifications. Confirm the exact scope in writing before you sign.
Do I need a PEC-registered engineer for my building?
For structural drawings submitted for approval, yes. Authorities in Punjab ask for structural design documents signed by a PEC-registered structural engineer.
Which building code is used for design in Pakistan?
The Building Code of Pakistan, developed by PEC. The Seismic Provisions 2007 cover earthquake design, and BCP 2021 is based on the 2021 International Building Code. Ask your engineer which provisions they apply to your project.
Can I start construction before the plan is approved?
Construction without approval can lead to penalties or notices, and rules differ by authority. Check with your local authority before starting. Never rely on a contractor’s verbal assurance.
How long does construction design take?
It depends on size, building type and how quickly decisions and documents come from the owner. A small house takes much less time than a multi-storey commercial or industrial building. Ask the firm for a stage-wise schedule.
Is soil testing really necessary?
It is strongly recommended for any building beyond a basic single-storey structure, because engineers rely on it for foundation design. A soil test costs far less than a foundation failure.
Can Qalam Engineering design projects outside Lahore?
Yes, in the cities listed above. Local approval rules differ, so we check the requirements of your city’s authority at the start of each project.
Sources
- Pakistan Engineering Council: Building Code of Pakistan
- International Code Council: BCP 2021 announcement
- Lahore Development Authority: building regulations